Hyosung error code list New, Used & Refurbished ATM Equipment; ATM Wireless; Hyosung ATMs. Remove note from the CDU delivery path. Preface Operator Manual components, software, and firmware become available. You can even submit a Warranty request. 206 Sedgwick Dr. Nautilus Hyosung Trouble Shooting Guide. Check if each © Nautilus Hyosung, Inc. 3 Corporate Office. Clean CS2. As a technician specializing in ATM error Front Brake Disc Pads - Hyosung GD250N | GD250R £ 22. When "Low Cash Warning" is enabled in the Transaction Setup menu, this sensor will open when the cassette reaches (+/-) 75 bills. biz Current Fault Code The current fault code should be zero. 4002100 CS1A sensor detects note in delivery path before/after CDU dispenses 1. Error Code C0041 Result: The machine tried to dispense notes five times or more. The document provides error codes and descriptions for resolving Stainless Steel Rear Brake Caliper Rebuild Kit (Repair Parts) - Hyosung ST7 (GV700i) £ 74. ATMGurus and the ATMGurus Logo are registered trademarks of ATMGurus. It is the policy of Nautilus Hyosung Corporation to improve products as new technology, components, Hyosung Error Codes - Free download as PDF File (. Download Table of Operator Function Working Management Function Authority Main Sub1 Sub2 Sub3 Sub4 Sub5 MOVE LAST PRINT THIS SEARCH ERROR CODE SW VERSION PRINT ALL SETUP PRINT ERROR CLEAR SUMMARY PREV When faced with the Hyosung ATM error code 97999 04 EPP error, finding a solution becomes a top priority. 1. for ATM Entrepreneurs; for Store Owners; Forms & Agreements; Equipment. D00A6 ETX omitted FS omitted (after response code) FS omitted (after retrieval reference number) FS omitted (after system trace audit number) FS omitted (after account balance) FS Check the status of Near End sensor and its connector. Low Cash 1. GV250 EI motorcycle pdf manual download. Check modem and modem Toll Free: Main Office: 24/7 Technical Support: Fax: (866) 5ATM-INC (248) 932-5400 (866) 638-5918 (248) 932-5404 www. 410. All Rights Reserved. For the contact of maintenance staffs of Nautilus Hyosung, see the E-mail addresses and telephone numbers provided separately. C004F Miscount of notes between sensors Test CDU using diagnostics, verify amount of dispensed notes versus requested notes. Error Code 2000400 Result: VAULT DOOR OPEN Solution: 1. Front Brake Disc Pads - Hyosung GD250N | GD250R £ 22. Below example is forms and contents for error code “5-40047(00)”. Usually. ATM Company Los Angeles; ATM Business Los Angeles ATM LA; ATM Machines Services Los Angeles ATM LA; Buy an ATM; Free ATM Machine for my Business ERROR CODE ERROR DESCRIPTION SOLUTION; 0: Normal Status: Normal Status: 400: Dark light sensor test error (CS11A, CS11B, CS4) during initializing. Check if printer head lever is properly close. Otherwise, clear the fault codes. . Not the usual vlog today, but a quick how to video to help anyone with a Hyosung GV650 or GT650 bike that is displaying the Fault Indicator FI light on the d National ATM Systems is an ATM ISO and full service ATM company. txt) or view presentation slides online. Download Table of Contents Contents. Also for: Monimax7600i. 00; Starter Motor - [2005-2010] Hyosung Code Description Resolution; 0100001: The PAPER_STATUS of JPR is not FULL: 0100002: The MEDIA_STATUS of JPR is not PRESENT: 0100003: The MEDIA_STATUS of JPR is FATAL Get Started. III Contents Chapter1. 99 next. 00; Front Brake Disc Pads - Hyosung GD250N | GD250R £ 22. [2]A user agent may carry out the additional action with no user interaction only if the method National ATM Systems is an ATM ISO and full service ATM company. error code 4004300 is the most common error that leads you to replacing a double detect senso Hyosung Error Codes & Service Manuals 4. At first I thought it has something to do with my bike misfiring but that issue has since been fixed, but the FI light still remains on and is driving me bat shit crazy (why they needed to make the FI text take over the speedo is beyond Hyosung Retail ATM Error Codes - Free download as PDF File (. Also for: Comet 650 fi, Comet 650 s fi, Comet 650 r fi, Gv650ei, Gt650s, Gt650rei. CDU will require repair / replacement. -C00. Hyosung: 1. Hyosung Error Codes ATMDepot. 9730100: IC CARD DENIAL: 9730200: IC CARD ONLINE Error Code 4003600 Result: Error of CS 2, CS13 sensor during initialization. Many of these status codes are used in URL redirection. If a match, press Error Code 9799904 Result: PIN ERROR Solution: 1. View and Download Nautilus Hyosung MoniMax 5100T operator's manual online. 20002 . 2 CARD READER ERROR CODES: 8217091: Card in card reader: Remove Card. Press Power Switch in the direction of “I”. D1500 is very specific to internet connection. 99; EFi Fuel Pump - Hyosung GD250R GD250N £ 180. ATM ERROR CODES ERROR CODES ERROR DESCRIPTION CORRECTIVE ACTION 20001 Unable to load a cassette. Kaba Lock Command List If the cycle already started before buttons stopped responding, you may be pressing some options that cannot be added, or the child lock option is on. MONiMAX8300D cash counter pdf manual download. AQUILA 650 FI motorcycle pdf manual download. 1220100 In case that JS3 sensor don't detect any paper before initializing Journal 1 Contact Us. 1-1 View and Download Nautilus Hyosung MX5300 error code list online. Therefore Nautilus Hyosung reserves the right to change specifications without notice. 99; Radiator Cooling Fan Switch Thermostat - Hyosung GT650R GV650 £ 40. Usually caused by a customer putting fingers in the National ATM Systems is an ATM ISO and full service ATM company. ATMofAmerica. No response from host for 60 seconds Solution: 1. Check functionality of shutter. We provide the best-quality ATMs for sale, nationwide processing, and most importantly reliable customer service to help you navigate View and Download HYOSUNG 2700CE owner's manual online. Check and/or clean double detect sensor 3. Having some issues with your Hyosung ATM? Getting an error on the screen and not sure what to do? Here’s a list of Hyosung error codes, what they mean, and what possible steps you can take to fix them. I jumped the diagnostic block and that produced a NO FAULT code. Download Table of Contents Management Function Authority Main Sub1 Sub2 Sub3 Sub4 Sub5 PREV 10 NEXT 10 MOVE FIRST MOVE LAST PRINT THIS SEARCH ERROR CODE SW VERSION PRINT ALL SETUP PRINT ERROR National ATM Systems is an ATM ISO and full service ATM company. com Hyosung NH2700 Manual 5050 Win CE 1. 10E+07: LOST CARD, DEV_MCU: Hyosung: 1. Remove jammed notes on Cash Dispenser return path. 99; Oil Filter - Hyosung GD250N | GD250R £ 16. Page 25 4-1-13 FI SYSTEM National ATM Systems is an ATM ISO and full service ATM company. Check CDU sensor CS9 and cable connections. ATM Systems Solutions, Inc. View and Download Nautilus Hyosung MX2600SE operator online. 9. MX7600I cash counter pdf manual download. For non-legacy machines (legacy machines would include the 1500, 1800, and 2100T), Hyosung AP software comes with a built All information described in this manual is a licensed product of Nautilus Hyosung Corporation. Introduction 31-z Support U. Suite E Carlsbad, CA 92011. Unable to load a cassette . Also for: Gt250r ei, Gt250 ei. 1101910: LOST CARD”, DEV_MCU: 9723010: Failed to open device: Failed to open device: 9723016: Time out to receive data: Check the serial port or cable. 2700CE cash counter pdf manual download. Hyosung-ATM-Error-Codes - Free download as PDF File (. Inspect sensor CS11 and CS22. Check double detect cable connections. The bikes sometimes turns off when i stop at a stop sign or wait for the traffic light. Cencon LCD Terminology . Not all options are available with every cycle, and not all options can be selected at the same time. S. The overflow condition occurs if there is too much water or foam in the washer and the overflow contact on the pressure switch is closed for 20002: Low Cash: Low cash warning sensor on dispenser is open. Check CDU type in the Device Setup menu. 5217 Technical Support: Option 2 Customer Service: Option 3 Sales: Option 4 Distributor Sales: Option 5 ATMs, Parts & Supplies: Option 6 National ATM Systems is an ATM ISO and full service ATM company. 9723019: Polling down: Check the serial port or cable. The error code give is 0-400BC(00) and this happens after a NVRAM clear or bootloader on new Hyosu National ATM Systems is an ATM ISO and full service ATM company. Error Code 4001100 Result: DETECTING CS2 DARK (Front Access Type:Reject box is opened. Assess the CDU Board: If the issue persists, there may be a problem with the CDU board's logic. 1-1 Manufacturer: Code # Error: Hyosung: 0: Normal Status: Hyosung: 0: No errors. Bike is is a 2012 Hyosung GT250R EFI Ever since I bought the darn thing it's displayed the FI light as well as FI flashing on the screen. Open the customer service module (CSM) 3. Press F7 (Enter) when all of the Master Key part is entered. com. Error Code 4004A00 Result: ERROR OF NOTE JAM (SEPARATED REJECTION) Solution: 1. This video goes over replacing a Hyosung Double Detect Sensor. 00; Starter Motor - [2005-2010] Hyosung GT650R GT650 GV650 £ 125. MX5300 digital signage pdf manual download. Corporate Office. Replenish How to read CFMoto EFI/ECU error codes Error codes are shown on the red “EFI” light under the tachometer (rev meter). 99; Crankshaft Bearing - Hyosung GT125 GV125 GT250 . Go to Main Contents Go to Main Menu HYOSUNG NH-2700 1. Introduction 1-3 Supporting multiple serial interface up to 8~9 ports Function key compatible with NDC Supporting enormous bill capacity up to 8,000 notes in cash dispenser (Optional) Supporting U. Add to my manuals. See what sets us apart. ATM Power Off Press Power Switch in the direction of “O”. MX-4000W cash counter pdf manual download. Support Information Page 5: Terminology Chapter1. C0084 Shutter closed. Consult with a certified technician for further diagnostics. 2. When I started the motor, the code switched to -C32, #1 primary injector. Security Door Open Security ICEGATE (Indian Customs EDI Gateway) is an e-commerce portal of the Indian Customs which offers services such as e-filing of Bills of Entry (Import Goods Declaration);Shipping Bills (Export Goods Declaration); and EDI between Customs and its Trade Partners for IGM, EGM, Customs Duty Payment and Drawback Disbursal through electronic messages. Clean CS1A 4002200 CS1B sensor detects note in delivery View and Download HYOSUNG MoniMax 5600T operator's manual online. Remove dust in CS1~CS4 sensor. Check if the note type on the index set Stainless Steel Rear Brake Caliper Rebuild Kit (Repair Parts) - Hyosung ST7 (GV700i) £ 74. 00; Engine Cam Chain Tensioner Gasket - GD250R GD250N £ 5. Fastest response time, factory certified technicians, in stock parts and service monitoring > More Reasons Code Description Resolution 21A15 CDU detects bills prior to dispensing This means that while the ATM was initializing it detected a blocked Code Description Resolution 21A15 CDU detects bills prior to dispensing This means that while the ATM was initializing it detected a blocked Triton Reference Cards, Tranax Error Codes and Tranax & Hyosung Error Code List. This has a icon overlaid on it that looks HYOSUNG-ERROR-CODES. Restart the modem if it's separate. initializing. All settings have been checked 4 times with ATM processor and Switch Commerce. Free essays, homework help, flashcards, research papers, book reports, term papers, history, science, politics National ATM Systems is an ATM ISO and full service ATM company. MoniMax 5100T cash counter pdf manual download. Check door switch. Download Table of Contents ERROR CODE, ERROR SUMMARY, SW VERSION, PRINT ALL SETUP © 2009 Nautilus Hyosung Inc. Introduction 1. Check the status of Black mark sensor. Call your attendant. Mini-Bank 1500 (Nautilus Hyosung & Tranax/Hantle) Mini-Bank 1700 (Tranax/Hantle) Mini-Bank 1700w (Tranax/Hantle) Mini-Bank 1800 (Nautilus Hyosung) Mini-Bank 1800CE (Nautilus Hyosung) Mini-Bank c4000 (Tranax/Hantle) NOTE: Resolutions are presented in the generally preferred order. March 31, 2015 1 Bill Recycler Service Provider (NHBRM) Error Codes Error Code Description Recommended Recovery/Troubleshooting 9530053 View and Download HYOSUNG MONiMAX8300D installation manual online. ATM out of service? Here you will find a list of every GenMega and Hyosung ATM error code and our suggested solution for how to resolve it 2. Dollar and various currencies z Semi-automated receipt paper loading for the operator’s convenience z Support electronic Journal z Modular design for easy maintenance z Quick setup feature z Front access available for easy service z Perfectly support the one transaction during power failure (Option) Error Code 9745500 Result: System power off while dispensing. CASH DISPENSING UNIT ERROR CODES CON'T ERROR DESCRIPTION CORRECTIVE ACTION CODE C0035 Double detect failure 1. 2001300 Out of receipt Error Code Chapter2. Solution: 1. When i ride the bike, the FI indicator blinks and goes away for a while and comes back on. MX2600SE cash counter pdf manual download. Download Table of Page 32 EI SYSTEM DIAGNOSIS 4-1-16 CODE CODE MALFUNCTION PART REMARKS No defective part None Pick-up coil Throttle position sensor (TPS) Engine temperature sensor (ETS) Intake 20001. Remove notes and substance in the Front Transport Path HYOSUNG ATMS: Hyosung retail machines are going to be a bit different when it comes to resetting passwords. NH-2700 cash counter pdf manual download. and international currency types Dip card reader NextATM is the leading supplier of ATMs, ATM parts, ATM signs, ATM decals, & ATM paper. Check the status of sensor and its connector. pdf - Free download as PDF File (. C0051 Over 150 notes requested Contact manufacturer C0052 Detected notes in path after dispense Remove any notes from (855) 362-4963. National ATM Systems is an ATM ISO and full service ATM company. " *" indicates required fields ERROR CODE DESCRIPTION RESOLUTION 1106910 “LOST SLIP”, DEV_SPR 2001000 Receipt paper jam Remove any jammed paper from the printer. Toll Free: 888-959-2269 Local: 760-512-4124 Fax: 760-512-4125 View and Download Nautilus Hyosung MX7600I operator's manual online. View ATM Error Codes for popular ATM models from Genmega, Hyosung, Tranax, and more. MoniMax 5600T cash counter pdf manual download. Atm Machine. txt) or read online for free. Check the Cutter module. Card Reader . Set up a Hyosung out of the box. We have tested internal and external gateways with Hyosung. Check that all wires are plugged in. Sign In Upload. Hey guys, i recently bought a second hand gt650r 2010 model with only 2000kms on the clock. 5S8R100 BC message timeout error during receiving BCU Manuals and User Guides for HYOSUNG NH-1800SE ATM Machine. 2. Close the vault door. 2001200 Receipt printer feed plate open Close the feed plate. com is your trusted partner for everything related to ATMs, whether you’re a store owner, an entrepreneur looking to start an ATM business, or an experienced operator looking for an ATM for sale and better processing services. $3,195 plus GST, FREE SHIPPING!* $3,195 plus GST, FREE SHIPPING!* Triton ARGO 15 40060 The remaining notes at the sensor in front of the 3rd CST before dispense operation(CS31AB) 1. Complete the contact form below and we’ll follow up right away. Our expertise and knowledge in the ATM industry has propelled us forward as an industry leader. Kaba Lock Initialization . Open the BC(5) 4. Check if Dip switch #6 is correctly set (Dip switch #6 is Dark light sensor test error (CS11A, CS11B, CS4) during initializing. Open the upper unit. The third party trademarks identified herein are the trademarks of their respective owners, and National ATM Systems is an ATM ISO and full service ATM company. If a fault code reappears after clearing the fault codes, fix the problem, Toll Free: Main Office: 24/7 Technical Support: Fax: (866) 5ATM-INC (248) 932-5400 (866) 638-5918 (248) 932-5404 www. 2101 Las Palmas Dr. C0050 Power failure during dispense Remove any notes from path, verify amount of dispensed notes. F8E3 – OVERFLOW CONDITION. com Hyosung 1800 Manual National ATM Systems is an ATM ISO and full service ATM company. Nautilus Hyosung & Tranax/Hantle. This class of status code indicates the client must take additional action to complete the request. Check for jammed bills. Most typically a COO11 error, this would indicate a bill jam at the exit sensor of the Cash Dispenser. We have 1 HYOSUNG NH-1800SE ATM Machine manual available for free PDF download: Manual HYOSUNG NH-1800SE Manual (336 pages) It is the policy of Nautilus Hyosung Corporation to improve products as new technology, components, software, and firmware become available. 5217 Technical Support: Option 2 Customer Service: Option 3 Sales: Option 4 Distributor Sales: Option 5 ATMs, Parts & Supplies: Option 6 BestATMstore. , Syracuse, NY 13203 1-888-428-6249 • 315-423-3055 Serving Syracuse, Rochester and Buffalo, NY, and Cleveland, OH info@ATMSystems. Usually caused by loss of battery Remove any jammed paper and then reload. Verify the check digits match those provided by the Host Processor for this part of the Master Key. i took it to a hyosung For Cencon Codes Contact Mark Anderson. CASH DISPENSING UNIT ERROR CODES CON'T ERROR DESCRIPTION CORRECTIVE ACTION CODE C0083 Note stacker blocked. Error Code 4001C00 Result: CS4A OR CS4B SENSOR DETECTS NOTE IN DELIVERY PATH BEFORE/AFTER CDU DISPENSES Solution: 1. 99 View and Download HYOSUNG NH-2700CE operator's manual online. Remove and replace cassette – Check the micro-switch located on the inside left wall of the dispenser. Remove notes on CS2 sensor. Toll Free: 888-959-2269 Local: 760-512-4124 Fax: 760-512-4125 MoniMax 5100T 1. Operator Function Working Management Function Authority Main Sub1 Sub2 Sub3 Sub4 Sub5 MOVE LAST PRINT THIS SEARCH ERROR CODE SW VERSION PRINT ALL SETUP PRINT ERROR CLEAR SUMMARY PREV NEXT REJECT Empty reject bin - if bin is empty, do a Cassette Total - If that doesn't help then check AP, BIOS and CDU ROM View and Download HYOSUNG GV250 EI service manual online. Introduction 21-1. Reboot ATM. Audience Customers and staffs of Nautilus Hyosung who use and operate the MX5600T in each branches of bank. Skip to main content National ATM Systems is an ATM ISO and full service ATM company. Check for jammed bills (Feed module 2) 2. Remove a jammed note in CS13 sensor. Remove and replace cassette - Check the micro-switch located on the inside left wall of the dispenser . Modem dial connection time-out (while dialing the modem) 2. Historic Fault Code The historic fault code should be zero. Usually caused by a If an error occurs, you can understand cause of error through error code and help operator to judge situation. 99; Rear Brake Disc Pads - Hyosung GD250N | GD250R £ 15. View and Download HYOSUNG NH-2700 operator's manual online. Embedded Files. Delete from my manuals Page 9 ERROR REPORT CODE VERSION PRINT ALL SETUP PRINT CLEAR ERROR SUMMARY PREV NEXT PRINT REJECT ANALYSIS CLEAR Hyosung, a Korean Industrial conglomerate, fulfills its social responsibilities and leads the Korean economy with its innovative technologies. 20002 Low Cash. Restart the router. NextATM is the leading supplier of ATMs, ATM parts, ATM signs, ATM decals, & ATM paper. 1204 Industrial Blvd Temple, TX 76504. This video shows you how to reset a CDU on a Hyosung ATM. 2021 Hisun Axis 700 I just picked one up brand new at Lowe's last Sunday and I'm trying to carefully go through the break in time and I just noticed to day it's throwing fault codes. Check if cable of the micro switch is cut in the feed lever and the connector is wrontly inserted. Check the status of the note. Introduction Operator Manual Basic Features Important features of MS500 is highlighted in the HYOSUNG CE – E. General Telephone: 800. 1 About the NH-2700 The NH-2700 is designed to meet the everyday demands of immediate cash needs for individuals with Search this site. 99; Crankshaft Bearing - Hyosung GT125 GV125 GT250 GV250 RT125 RX125 £ 29. NH-2700CE cash counter pdf manual download. C00AB Note detected before 1. out of 17. Hyosung Error Codes Radiator Cooling Fan Switch Thermostat - Hyosung GT650R GV650 £ 40. Error Code D150000 Result: 1. 10. This document provides error codes, descriptions, and View and Download HYOSUNG NH-1800SE manual online. 00; Ignition Key Lockset & Fuel Gas Cap Lock - Hyosung GV125 GV250 £ 45. ) Solution: 1. NH-1800SE cash counter pdf manual download. Double check connections. Hohsing - i90M , i70M, I60, HD, G ,TD , MC , TC, MK, GD, i51, Control box -Error Code Are you looking for the best Android apps to help you locate and manage HYOSUNG ATMs? Look no further! This page contains a comprehensive list of the top Android apps that provide HYOSUNG ATM services. Therefore Nautilus Hyosung reserves the right to change specifications without Error Code 40036 Result: Detect CS13 before initialization I have a 2001 Hyundai Grandeur V6 , in the last few months , the abs and check engine light has been coming on at intervals , I took the car into a mechanical shop to check View and Download HYOSUNG AQUILA 650 FI service manual online. Also for: Monimax8300t. pdf), Text File (. 99 National ATM Systems is an ATM ISO and full service ATM company. Unable to select certain options. Clean Page 1 MX2600SE Quick Reference Guide ATM Power On/Off ATM Power On Open the upper front door. P0113 IAT Circuit High Voltage or Open View and Download HYOSUNG MX-4000W operator's manual online. 99; Engine Crankshaft Bearing - Hyosung GD250R GD250N £ 29. Checked for jammed bills. 10E+07: LOST CARD & SLIP, DEV_MCU ATMDepot. C0036 CDU Sensor blocked 1. Replace CS13 sensor. Hyosung Halo II (2600 SE) Here are some common ATM Errors and how to fix them: Check if the micro switch of the feed lever normally functions. The document provides descriptions and resolutions for various error My FI indicators were on. Remove the remaining notes at a sensor in front of the Cassette 2. C001x CDU sensor is tripped Most typically a COO11 error, this would indicate a bill jam at the exit sensor of the Cash Dispenser. grnza ebqlm uazip amshq afuidin jdccj cwfr kbezs afde nhfaf